Hitachi GLS Chiller Unit, Air-Cooled, Matrix Sigma Low Temperature

Chiller Matrix Sigma with new refrigerant R32, designed for low-temperature brine specifications.

Overview The new refrigerant R32 Matrix Sigma, designed with consideration for environmental impact and improved energy efficiency, has been newly introduced in the low-temperature blind specification series. Features - Adoption of the new refrigerant R32. - New lineup of 1800 and 2000 models. - Reduced risk of complete shutdown. - Improved energy efficiency and cooling capacity, enhancing replacement compatibility. - Standard equipped with modular control functions compatible with various local systems. - Easy setup and inspection with a touch panel. - Options available for both standard installation types and renewal installation types (custom orders accepted). Adoption of the new refrigerant R32 The refrigerant used is the new refrigerant R32, which reduces the global warming potential by approximately 67% compared to the conventional refrigerant R410A. This aims to reduce environmental impact. Composed of multiple independent refrigeration cycles in one module In the unlikely event that one refrigeration cycle fails, the other normal refrigeration cycles will continue to operate. For more details, please contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Hitachi GLS Chiller Unit, Brine Water-Cooled, Cooling Only, Low Temperature, Constant Speed

Water-cooled low-temperature brine chiller using R407C with an ozone depletion potential of zero.

Adoption of environmentally friendly refrigerants We have adopted the HFC refrigerant R407C, which has an ozone depletion potential of zero. Enhanced control functions By incorporating electronic circuits into the control circuit, we have enhanced functions such as operating pressure display, brine inlet and outlet temperature display, and individual alarm display. Compressor rotation function (RCUP450・600・900L2) We have changed the base operating machine of the compressor to equalize the operating time across each compressor. Momentary power interruption recovery control In the event of a momentary power outage, the system will automatically resume operation in the mode prior to the outage after recovery. Switchable to outlet temperature control The system is set to brine inlet temperature control at the time of shipment. If brine outlet temperature control is required for the factory's production process cooling, it can be changed through the main unit's switching operation. [Brine temperature control] You can select the return temperature difference for temperature adjustment (thermostat ON/OFF difference) from 2, 3, or 4°C.

  • Heating and cooling equipment and facilities
  • Blind chiller unit

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration